厨房水电按装阶段
卫生间
卫生间
所有线管,采用直径20中型线管。同一根线管内穿线不得超过7根
https://www.gtzs.com/data/attachment/forum/202310/31/092037ahm36ohu6bkolo6m.jpg
https://www.gtzs.com/data/attachment/forum/202310/31/092037v444ncz4ggpngg4t.jpg
顶部交接处用八角盒和杯梳连接线管,可以防止电线被箱、盒的开口处划伤
https://www.gtzs.com/data/attachment/forum/202310/31/092449gjr2bq7dn0oqsqz7.jpg
地面线管并排2根以上管卡错位顺钉,间隙均匀
强弱电相距30公分以上,强弱电交接处用金属屏蔽管
https://www.gtzs.com/data/attachment/forum/202304/28/135650tprao6r59ruook6q.jpg
同一房间内插座开关水平高低≤5毫米,并排在一起的开关、插座必须保持横平竖直,必须要接地线。插座内左零右火,上接地
https://www.gtzs.com/data/attachment/forum/202304/28/135822yjaaaatai8zqtae8.jpg
水管吊卡间距应小于80cm 转角处必须要有吊卡
https://www.gtzs.com/data/attachment/forum/202305/05/110456jfpuojbxzovseo9o.jpg
师傅做管道安装应横平竖直,厨房,卫生间走墙水管采用下垂式安装。
https://www.gtzs.com/data/attachment/forum/202305/05/110556zjiiiijszijigysi.jpg